Technical parameters:
|
operating voltage |
AC 220V±10% 50Hz |
| electric power consumption |
2.3KW |
|
constant temperature |
(20±5)℃. Inlet and outlet air flow (5000±500)L/min, adjustable |
| air flow |
0-30m3/min adjustable |
|
air supply |
Propane(0.1Mpa), Air(0.1Mpa), Gas source provided by customer |
| Timing range |
0-60min can be set |
|
Anemometer Measuring Range |
0-30m/s |
| Measurement accuracy |
±0.2m/s |
|
Test chamber size |
Length 2184mm, Width 1156mm, Height 5213mm |
| Dimensions of standard steel ladder for testing (vertical) |
500(W)×3,500(H) |
|
Wide steel ladder dimensions (vertical) |
800(W) x 3,500(H) |
| Burning surface size |
(L)257×(W)4.5 mm |
|
Main components |
Combustion box (with ash hopper and drainage tank), 2 combustion ladders (800mm, 500mm each), 2 341mm blowtorches (with venturi mixer), 1 fixed blowtorch traveling trolley, electric combustion ladder lifting and lowering system, 1 frequency control inlet axial blower, 1 set of air volume measurement system, 2 water sprinkler pipelines, 2 nitrogen fire extinguishing pipelines, and 1 operation desk. |
|
spray tower |
1 unit |
| Smoke exhaust fan |
1 unit |
|
2 sets of burning lamp heads |
|
|
Intelligent control, electronic ignition, automatic timing |
|
|
PLC control of the burner, touch screen operation |
|



SLGSG-600型管状输送带横向刚性及重复刚性试验机-500x500.png)


SR-1000型实验室规模燃烧特性试验箱-500x500.png)